CKFTB - 1401 BRIGHT SILVER KRYLON DECORATOR METALLICS

Product Identification

Product ID:1401 BRIGHT SILVER KRYLON DECORATOR METALLICS
MSDS Date:09/01/1996
FSC:NIIN:Submitter:D DG
Status Code:A
MSDS Number: CKFTB

Responsible Party
SHERWIN WILLIAMS, DIVERSIFIED BRANDS INC.
31500 SOLON ROAD
SOLON, OH 44139
US

Emergency Phone: 216-566-2917

Info Phone: 800-832-2641/247-3270

Cage: PO273

Contractor
SHERWIN WILLIAMS, DIVERSIFIED BRANDS INC.
NONE SOLON, OH 44139 US

Telephone: 800-832-2641/247-3270

Cage: PO273

Ingredients

PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1800 MG/M3;1000 PPM


LIGHT ALIPHATIC HYDROCARBON SOLVENT (13%) AND V.M.&P.

CAS: 64742-89-8


MINERAL SPIRITS

CAS: 64742-88-7


TOLUENE

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL see Table Z-2

ACGIH TLV: 188 MG/M3;50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETONE

CAS: 67-64-1

RTECS: AL3150000

OSHA PEL 2400 MG/M3;1000 PPM

ACGIH TLV: 1780 MG/M3;750 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATION OF EYES, SKIN AND
RESPIRATORY SYSTEM. MAY CAUSE NERVOUS SYSTEM DEPRESSION. EXTREME
OVEREXPOSURE MAY RESULT IN UNCONSCIOUSNESS AND POSSIBLY DEATH.
PROLONGED OVEREXPOSURE TO SOLVENT INGREDIE NTS MAY CAUSE ADVERSE
EFFECTS TO THE LIVER, URINARY, BLOOD-FORMING, CARDIOVASCULAR, AND
REPRODUCTIVE SYSTEMS. REPORTS HAVE ASSOCIATED REPEATED AND
PROLONGED OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRA IN AND
NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NO INGREDIENT IN THESE PRODUCTS IS AN
IARC, NTP OR OSHA LISTED CARCINOGEN.
Effects of Overexposure:HEADACHE, DIZZINESS, NAUSEA, AND LOSS OF
COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO VAPORS OR
SPRAY MISTS. REDNESS AND ITCHING OR BURNING SENSATION MAY INDICATE
EYE OR EXCESSIVE SKIN EXPOSU RE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:IF INHALED: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE
BREATHING. KEEP WARM AND QUIET. IF ON SKIN: WASH AFFECTED AREA
IMMEDIATELY WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND
LAUNDER BEFORE R EUSE. IF IN EYES: FLUSH EYES WITH LARGE AMOUNTS OF
WATER FOR 15 MINUTES. GET MEDICAL ATTENTION. IF SWALLOWED: NEVER
GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. GIVE SEVERAL
GLASSES OF WATER. SEEK MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:<-17.6C, 0.F
Lower Limits:0.9
Upper Limits:12.8
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM
Fire Fighting Procedures:CLOSED CONTAINERS MAY EXPLODE (DUE TO THE
BUILD-UP OF PRESSURE) WHEN EXPOSED TO EXTREME HEAT, ISOLATE FROM
HEAT, ELECTRICAL EQUIPMENT, SPARKS AND OPEN FLAME. APPLICATION TO
HOT SURFACES REQUIRES SPECI AL PRECAUTIONS. DURING EMERGENCY
CONDITIONS OVEREXPOSURE TO DECOMPOSITION PRODUCTS MAY CAUSE A
HEALTH HAZARDS.
Unusual Fire/Explosion Hazard:FULL PROTECTIVE EQUIPMENT INCLUDING
SELF-CONTAINED BREATHING APPARATUS SHOULD BE USED. WATER SPRAY MAY
BE INEFFECTIVE.IF WATER IS USED, FOG NOZZLES ARE PREFEREABLE. WATER
MAY BE USED TO COOL CLOSED CO NTAINERS TO PREVENT PRESSURE BUILDUP
AND POSSIBLE AUTOIGNITION OR EXPLOSION WHEN EXPOSED TO EXTREME
HEAT.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.

Handling

Handling and Storage Precautions:CONTENTS ARE EXTREMELY FLAMMABLE. KEEP
AWAY FROM HEAT, SPARKS, & OPEN FLAME. VAPORS WILL ACCUMULATE
READILY & MAY IGNITE EXPLOSIVELY. KEEP AREA VENTILATED. DO NOT
SMOKE. EXTINGUISH ALL FLAMES. CONTENT S UNDER PRESSURE. DO NOT
PUNCTURE, INCINERATE, OR EXPOSE TO TEMPERATURE ABOVE 120F.
Other Precautions:HEAT FROM SUNLIGHT, RADIATORS, STOVES, HOT WATER, AND
OTHER HEAT SOURCES COULD CAUSE CONTAINER TO BURST. DO NOT TAKE
INTERNALLY. KEEP OUT OF REACH OF CHILDREN. INTENTIONAL MISUSE BY
DELIBERATELY CONCE NTRATING AND INHALING THE CONTENTS CAN BE
HARMFUL OR FATAL.

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA FOR PROTECTION
AGAINST INGREDIENTS. WHEN SANDING OR ABRADING THE DRIED FILM, WEAR
A DUST/MIST RESPIRATOR APPROVED BY NIOSH/MSHA FOR DUST WHICH MAY BE
GENERATED.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF THE
EXPOSURE TO INGREDIENTS IS MAINTAINED BELOW APPLICABLE EXPOSURE
LIMITS.
Protective Gloves:WEAR GLOVES WHICH ARE RECOMMENDED BY GLOVE
MANUFACTURER FOR PROTECTION AGAINST
Eye Protection:WEAR SAFETY SPECTACLES WITH UNPERFORATED SIDESHIELDS.
Supplemental Safety and Health
SAX ARTS P/N: 317-0107

Chemical Properties

HCC:V3
Vapor Density:>AIR
Volatile Org Content %:45
Spec Gravity:0.77 - 0.95
Evaporation Rate & Reference:FASTER THAN ETHER

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE

Disposal

Waste Disposal Methods:WASTE FROM THESE PRODUCTS MAY BE HAZARDOUS AS
DEFINED UNDER THE RESOURCE CONSERVATION AND RECOVERY ACT (RCRA)
40CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE THE
APPLICABLE EPA HAZARDOUS WASTE NUMBERS. DO NOT INCINERATE.
DEPRESSURIZE CONTAINER. DISPOSE OF IN ACCORDANCE WITH FEDERAL, ST
ATE AND LOCAL REGULATIONS.

Regulatory

Federal Regulatory Information:ALL CHEMICALS IN THESE PRODUCTS ARE
LISTED, OR ARE EXEMPT FROM LISTING, ON THE TSCA INVENTORY.
State Regulatory Information:CALIFORNIA PROPOSITION 65. WARNING: THESE
PRODUCTS CONTAIN CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER ADN BIRTH DEFECTS AND OTHER REPRODUCTIVE HARM.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.